Performances of the Virgo interferometer longitudinal control system
Year: 2010
Authors: Acernese F., Antonucci F., Aoudia S., Arun K.G., Astone P., Ballardin G., Barone F., Barsuglia M., Bauer Th S., Beker M.G., Bigotta S., Birindelli S., Bizouard M.A., Blom M., Boccara C., Bondu F., Bonelli L., Bosi L., Braccini S., Bradaschia C., Brillet A., Brisson V., Budzynski R., Bulik T., Bulten H.J., Buskulic D., Cagnoli G., Calloni E., Campagna E., Canuel B., Carbognani F., Cavalier F., Cavalieri R., Cella G., Cesarini E., Chassande-Mottin E., Chincarini A., Cleva F., Coccia E., Colacino C.N., Colas J., Colla A., Colombini M., Corda C., Corsi A., Coulon J-P, Cuoco E., D’Antonio S., Dari A., Dattilo V., Davier M., Day R., De Rosa R., Del Prete M., Di Fiore L., Di Lieto A., Emilio M. Di Paolo, Di Virgilio A., Dietz A., Drago M., Fafone V., Ferrante I., Fidecaro F., Fiori I., Flaminio R., Fournier J-D, Franc J., Frasca S., Frasconi F., Freise A., Gammaitoni L., Garufi F., Gemme G., Genin E., Gennai A., Giazotto A., Granata V., Greverie C., Guidi G., Heitmann H., Hello P., Hild S., Huet D., Jaranowski P., Kowalska I., Krolak A., La Penna P., Leroy N., Letendre N., Li T.G.F., Lorenzini M., Loriette V., Losurdo G., Mackowski J.-M., Majorana E., Man C. N., Mantovani M., Marchesoni F., Marion F., Marque J., Martelli F., Masserot A., Menzinger F., Mitchel C., Milano L., Minenkov Y., Mohan M., Moreau J., Morgado N., Morgia A., Mosca S., Moscatelli V., Mours B., Neri I., Nocera F., Pagliaroli G., Palomba C., Paoletti F., Pardi S., Parisi M., Pasqualetti A., Passaquieti R., Passuello D., Persichetti G., Pichot M., Piergiovanni F., Pietka M., Pinard L., Poggiani R., Prato M., Prodi G.A., Punturo M., Puppo P., Rabaste O., Rabeling D.S., Rapagnani P., Re V., Regimbau T., Ricci F., Robinet F., Rocchi A., Rolland L., Romano R., Rosinska D., Ruggi P., Salemi F., Sassolas B., Sentenac D., Sturani R., Swinkeles B., Toncelli A., Tonelli M., Tournefier E., Travasso F., Trummer J., Vajente G., van den Brand J.F.J., van der Putten S., Vavoulidis M., Vedovato G., Verkindt D., Vetrano F., Vicere A., Vinet J-Y, Vocca H., Was M., Yvert M.
Autors Affiliation: Ist Nazl Fis Nucl, Sez Pisa, I-56127 Pisa, Italy; CNRS, AstroParticule & Cosmol APC, F-75700 Paris, France; Univ Denis Diderot Paris VII, CEA, Observ Paris, IN2P3,UMR7164, Paris, France; EGO, I-56021 Cascina, Pi, Italy; CNRS, ESPCI, F-75005 Paris, France; Ist Nazl Fis Nucl, Sez Firenze, I-50019 Sesto Fiorentino, Italy; Univ Florence, Ist Nazl Fis Nucl, I-50121 Florence, Italy; Firenze Univ Urbino Carlo Bo, Ist Nazl Fis Nucl, I-61029 Urbino, Italy; Ist Nazl Fis Nucl, Sez Genova, I-16146 Genoa, Italy; Ist Nazl Fis Nucl, Sez Napoli, Naples, Italy; Univ Naples Federico 2, Ist Nazl Fis Nucl, I-80126 Naples, Italy; Univ Salerno, I-84084 Salerno, Italy; Ist Nazl Fis Nucl, Sez Perugia, I-6123 Perugia, Italy; Univ Perugia, Ist Nazl Fis Nucl, I-6123 Perugia, Italy; Univ Pisa, Ist Nazl Fis Nucl, I-56127 Pisa, Italy; Univ Siena, Ist Nazl Fis Nucl, I-53100 Siena, Italy; Ist Nazl Fis Nucl, Sez Roma, I-00185 Rome, Italy; Univ Roma La Sapienza, Ist Nazl Fis Nucl, I-00185 Rome, Italy; Ist Nazl Fis Nucl, Sez Roma Tor Vergata, Rome, Italy; Univ Roma Tor Vergata, Ist Nazl Fis Nucl, I-00173 Rome, Italy; Ist Fis Spazio Interplanetario IFSI INAF, Ist Nazl Fis Nucl, I-00133 Rome, Italy; Univ Aquila, Ist Nazl Fis Nucl, I-67100 Laquila, Italy; Univ Paris 11, CNRS, IN2P3, LAL, F-91898 Orsay, France; Univ Savoie, CNRS, IN2P3, Lab Annecy Le Vieux Phys Particules LAPP, F-74941 Annecy Le Vieux, France; CNRS, IN2P3, LMA, F-69622 Lyon, France; Natl Inst Subatom Phys, NL-1009 DB Amsterdam, Netherlands; Vrije Univ Amsterdam, NL-1081 HV Amsterdam, Netherlands; Univ Nice Sophia Antipolis, CNRS, Observ Cote Azur, F-06304 Nice, France; Univ Rennes 1, CNRS, Inst Phys Rennes, F-35042 Rennes, France; Ist Nazl Fis Nucl, Grp Collegato Trento, I-35131 Padua, Italy; Univ Trent, Ist Nazl Fis Nucl, I-38050 Trento, Italy; Ist Nazl Fis Nucl, Sez Padova, I-35131 Padua, Italy; Univ Padua, Ist Nazl Fis Nucl, I-35131 Padua, Italy; IM PAN, PL-00956 Warsaw, Poland; Warsaw Univ, PL-00681 Warsaw, Poland; Astro Obs Warsaw Univ, PL-00478 Warsaw, Poland; CAMK PAM, PL-00716 Warsaw, Poland; Bialystok Univ, PL-15424 Bialystok, Poland; IPJ, PL-05400 Otwock, Poland; Inst Astron, PL-65265 Zielona Gora, Poland; Cardiff Univ, Cardiff CF24 3AA, S Glam, Wales; Eotvos Lorand Univ, ELTE, H-1053 Budapest, Hungary; Univ Birmingham, Birmingham B15 2TT, W Midlands, England
Abstract: The performances of the longitudinal sensing and control system of the Virgo gravitational wave detector are described. This system is able to stably maintain the RMS residual fluctuation of the interferometer longitudinal degrees of freedom around or below 10(-11) m, compatible with the original Virgo requirements. Moreover the detector sensitivity is not limited by longitudinal control noise at any frequency. Indeed the noise re-introduced by the longitudinal control system does not affect the Virgo design sensitivity. (C) 2009 Elsevier B.V. All rights reserved.
Journal/Review: ASTROPARTICLE PHYSICS
Volume: 33 (2) Pages from: 75 to: 80
More Information: The authors gratefully acknowledge the Support of the Italian Istituto Nazionale di Fisica Nucleare and the French Centre National de la Recherche Scientique for the construction and operation of the Virgo detector. The authors also gratefully acknowledge the support of the research by the Foundation for Fundamental Research on Matter of the Netherlands Organisation for Scientific Research, the Polish Ministry of Science and Higher Education grant N N203 387237, the FOCUS Programme of Foundation for Polish Science and the European Associated Laboratory Astrophysics Poland-France.DOI: 10.1016/j.astropartphys.2009.11.006ImpactFactor: 3.808Citations: 8data from “WEB OF SCIENCE” (of Thomson Reuters) are update at: 2024-10-13References taken from IsiWeb of Knowledge: (subscribers only)Connecting to view paper tab on IsiWeb: Click hereConnecting to view citations from IsiWeb: Click here