Soft laser-plasma X-ray source for differential absorption imaging of tracing elements in thin samples
Gizzi L.A., Cecchetti C.A., Galimberti M., Giulietti A., Giulietti D., Köster P., Labate L., Laville S., Tomassini P.
INO authors
Giulietti Antonio, Giulietti Danilo, Gizzi Leonida Antonio, Labate Luca, Tomassini Paolo
Abstract
The differential imaging technique is particularly suitable for the detection of small concentrations of contrasts agents for biological and medical applications in samples using X-ray radiography. In this paper, we present an application of this technique using a laser-plasma soft X-ray source combined with a bent crystal. Using a Fresnel plate as a test object, we were able to obtain spatial resolutions of the order of a few tens of microns. The use of our configuration to perform differential imaging of a test-sample at the L-2 edge of Br at 1,596 eV is finally demonstrated.
Affiliations
CNR, IPCF, Intense Laser Irradiat Lab, Area Ric, I-56124 Pisa, Italy;
Univ Pisa, Dipartimento Fis, Pisa, Italy;
Ist Nazl Fis Nucl, Pisa, Italy;
Univ Bologna, Dipartimento Fis, Bologna, Italy