Evaluation of a 3D diamond detector for medical radiation dosimetry

Anno: 2017

Autori: Kanxheri K., Servoli L., Oh A., Munoz Sanchez F., Forcolin G.T., Murphy S.A., Aitkenhead A., Moore C.J., Morozzi A., Passeri D., Bellini M., Corsi C., Lagomarsino S., Sciortino S.

Affiliazione autori: INFN Sez Perugia, Via A Pascoli 33, I-06123 Perugia, Italy; INFN Sez Firenze, Via G Sansone 1, I-50019 Florence, Italy; Univ Perugia, Dipartimento Fis, Via Pascoli 33, I-06123 Perugia, Italy; Univ Perugia, Dipartimento Ingn, Via G Duranti 93, I-06131 Perugia, Italy; Univ Florence, Dipartimento Fis, Via G Sansone 1, I-50019 Florence, Italy; Univ Manchester, Dept Phys, Oxford Rd, Manchester M13 9PL, Lancs, England; Christie NHS Fdn Trust, Wilmslow Rd, Manchester M20 4BX, Lancs, England; Manchester Acad Hlth Sci Ctr, Grafton St, Manchester M13 9NT, Lancs, England; INO CNR Firenze, Largo Enrico Fermi 6, I-50125 Florence, Italy; LENS Firenze, Via Carrara 1, I-50019 Florence, Italy.

Abstract: Synthetic diamond has several properties that are particularly suited to applications in medical radiation dosimetry. It is tissue equivalent, not toxic and shows a high resistance to radiation damage, low leakage current and stability of response. It is an electrical insulator, robust and realizable in small size; due to these features there are several examples of diamond devices, mainly planar single-crystalline chemical vapor depositation (sCVD) diamond, used for relative dose measurement in photon beams. Thanks to a new emerging technology, diamond devices with 3-dimensional structures are produced by using laser pulses to create graphitic paths in the diamond bulk. The necessary bias voltage to operate such detector decreases considerably while the signal response and radiation resistance increase. In order to evaluate the suitability of this new technology for measuring the dose delivered by radiotherapy beams in oncology a 3D polycrystalline (pCVD) diamond detector designed for single charged particle detection has been tested and the photon beam profile has been studied. The good linearity and high sensitivity to the dose observed in the 3D diamond, opens the way to the possibility of realizing a finely segmented device with the potential for dose distribution measurement in a single exposure for small field dosimetry that nowadays is still extremely challenging.

Giornale/Rivista: JOURNAL OF INSTRUMENTATION

Volume: 12      Da Pagina: P01003-1  A: P01003-14

Maggiori informazioni: This work has been partially supported by “Fondazione Cassa di Risparmio Perugia – Progetto 3Dose 2016.0107.021”.
Parole chiavi: Dosimetry concepts and apparatus; Leakage currents; Particle beams; Photoelectrons; Photons; Radiation damage; Synthetic diamonds, 3-dimensional structures; Charged particle detection; Diamond detectors; Dose-distribution measurement; Electrical insulators; Emerging technologies; Low-leakage current; Radiation resistance, Dosimetry
DOI: 10.1088/1748-0221/12/01/P01003

Citazioni: 8
dati da “WEB OF SCIENCE” (of Thomson Reuters) aggiornati al: 2024-12-01
Riferimenti tratti da Isi Web of Knowledge: (solo abbonati)
Link per visualizzare la scheda su IsiWeb: Clicca qui
Link per visualizzare la citazioni su IsiWeb: Clicca qui