INO
CNR
vai_a_storia   vai_a_organizzazione   vai_a_sedi   vai_a_personale   Area Riservata
    English English Version  
 
 

Valutazione analitica degli effetti di una pulitura laser: la statua di bronzo di Napoleone come Marte Pacificatore di Antonio Canova

  Articoli in atti di convegno  (anno 2017)

Autori:  Sansonetti A, Colella M., Letardi P., Salvadori B., Striova J

Affiliazione Autori:  ICVBC CNR, Via R.Cozzi, 53, 20152, Milano; ICVBC CNR, Via Madonna del Piano, Sesto Fiorentino; Servabo S.r.l., Via Luigi Canonica, 23, 20154, Milano; ISMAR CNR, Via de Marini, 6, 16149 Genova; INO CNR, Largo E. Fermi 6 Arcetri Firenze

Riassunto:  The laser cleaning on bronze artefacts is becoming a very promising conservation approach and its wider diffusion would benefit from further studies of effectiveness and harrmfulness. Some important references are available still the laser cleaning cannot be considered a traditional method on bronzes surfaces. In this paper, we report on the evaluation of the cleaning tests performed on an important Statue of Napoleon, depicted as Mars the Peacemaker, cast by Righetti in 1811 after a model by Antonio Canova. The sculpture is exposed in outdoor environment in the main courtyard of the Brera Gallery in Milan. The analytical survey on the corrosion products was carried out by means of XRD, μFTIR, μRaman; SEM observations equipped with EDS analyses were accomplished on cross sections. The results put in evidence the ubiquitous presence of brochantite Cu4(SO)4(OH)6. Antlerite Cu3SO4(OH)4 is also present sporadically. Residues of an acrylic, wax treatment (Incralac) and of proteins were highlighted by μFTIR. Laser cleaning tests were carried out with El.En. Combo, both in Long Q-switched (LQS) and Short free running (SFR) regimes. The evaluation of the effects of cleaning was carried out with a portable microscope and a reflectance colorimeter. Moreover a portable FTIR spectrometer was used in order to evaluate the presence of corrosion products after the cleaning. EIS (Electrochemical Impedence Spectroscopy) was used in the field on a selection of the tested areas in order to characterize the effect of laser cleaning on corrosion rate. A specially designed contact probe was used for measurements in the frequency range 100 KHz -10 mHz both before and after cleaning.

Titolo Conferenza:  Applicazioni laser nel restauro
Luogo:  Città del Vaticano
Tipologia articolo:  Articolo in Atti di convegno nazionale con referee
Parole chiave: laser cleaning - Nd:YAG - bronze sculpture - analytical methods - Electrochemical Impedence Spectroscopy
Collegamento Web del Prodotto: Clicca qui

INO © Istituto Nazionale di Ottica - Largo Fermi 6, 50125 Firenze | Tel. 05523081 Fax 0552337755 - P.IVA 02118311006     P.E.C.    Info